Critical power: Generators and generator system design

When designing generator systems, consulting engineers must ensure that the generators and the building electrical systems that they support are appropriate for the specific application.

02/13/2014


When designing generator systems, consulting engineers must ensure that the generators and the building electrical systems that they support are appropriate for the specific application. Whether providing standby power for health care facilities or prime power for rural processing plants, engineers must make decisions regarding generator sizing, load types, whether generators should be paralleled, fuel storage, switching scenarios, and many other criteria. In addition to being up to speed on the applicable codes, consulting engineers must work with the authorities having jurisdiction (AHJ) to ensure approval for the generator system is attained.

Learning objectives:

  • The audience will understand the applicable code requirements including NFPA 70: National Electrical Code and NFPA 110: Standard for Emergency and Standby Power Systems
  • Attendees will learn the criteria for selecting the appropriate generator or generators for the building type and/or application
  • Viewers will understand the criteria for designing the generator system, and know the differences between prime rated versus standby rated engines (U.S. EPA standards)
  • Viewers will learn the criteria for commissioning generators and the electrical systems they support.

Speakers:

James Ferris, PE, TLC Engineering for Architecture, Orlando, Fla.

Robert R. Jones Jr., PE, LEED AP, JBA Consulting Engineers, Las Vegas

Moderator: Jack Smith, Consulting-Specifying Engineer, Pure Power, and CFE Media, LLC



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me