Critical Power: Electrical systems and data center efficiency

Whether producing, consuming, or measuring and verifying (M&V), electrical systems play an important role in data center energy efficiency. When it comes to data center electrical efficiency, all sources of energy use in the facility must be considered.

06/02/2016


Whether producing, consuming, or measuring and verifying (M&V), electrical systems play an important role in data center energy efficiency. When it comes to data center electrical efficiency, all sources of energy use in the facility must be considered. In addition to the computers and servers, data center infrastructure includes both mechanical and electrical components—all of which "consume" energy and affect electrical efficiency. While energy use of many data center components may be obvious, understanding energy use of the electrical distribution system components can be elusive. It's important for engineers to know how the electrical system affects data center efficiency. Engineers must also balance power usage effectiveness (PUE) and electrical efficiency with reliability when designing data center electrical systems.

Electrical engineers may consider electrical meters, automatic and static transfer switches, uninterruptible power supply (UPS) systems, and powering IT equipment directly from utility power when determining and managing the amount of power used at various locations throughout the data center.

Learning objectives:

  • Explain data center energy production and its sources.
  • Interpret energy-efficiency electrical distribution components and topologies.
  • Assess electrical power management systems (EPMS) and power usage effectiveness (PUE).
  • Explain the applicable codes and standards: ASHRAE: Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings; IEEE 3006.7-2013: Recommended Practice for Determining the Reliability of 7x24 Continuous Power Systems in Industrial and Commercial Facilities; and NFPA 70: National Electrical Code (NEC).

Presenters:

Brian Rener, PE, LEED AP, SmithGroupJJR, Chicago

Ken Kutsmeda, PE, LEED AP, Jacobs, Philadelphia

Moderator: Amara Rozgus, Editor-in-Chief and Content Manager, Consulting-Specifying Engineer and Pure Power, CFE Media



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me