Critical Power: Circuit protection in health care facilities

Engineers must understand and apply circuit protection best practices especially when designing electrical systems in health care facilities.

08/08/2013


Health care facilities and hospitals have more stringent circuit protection requirements than conventional building electrical systems. Because of the unique constraints of health care facility electrical systems, design engineers must ensure these demanding requirements are met. However, codes adopted in many jurisdictions don't provide a significant amount of guidance regarding feeder and branch circuit design for health care facilities. Engineers must understand and apply circuit protection best practices especially when designing electrical systems in health care facilities.

Learning objectives:

  • The audience will understand the applicable codes: NFPA 70: National Electrical Code, Article 517, NFPA 99: Health Care Facilities Code, and NFPA 110: Standard for Emergency and Standby Power Systems
  • Attendees will understand the coordination, overcurrent, short-circuit, and ground-fault protection issues for health care facilities.
  • Viewers will learn about feeder protection design requirements for health care facilities.
  • Viewers will learn about branch protection design requirements for health care facilities.

Speakers:

Neal Boothe, PE, exp US Services Inc., Maitland, Fla.

James Ferris, PE, TLC Engineering for Architecture, Orlando, Fla.

Moderator: Amara Rozgus, Editor in Chief/Content Manager, Consulting-Specifying Engineer, Pure Power, and CFE Media LLC



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me