Critical Power: Backup power systems

Standby and emergency power systems provide power to ensure that life safety systems and critical equipment can operate during a power outage.

06/06/2016


Design engineers have many factors to consider when designing a backup system for a facility. Safety, maintainability, code compliance, and economics play crucial roles in determining the topology of a backup system for a critical facility. Specific requirements for backup power vary based on building occupancy type, facility use, and critical function. When designing generator systems, for example, engineers must ensure that the generators and the building electrical systems that they support are appropriate for the specific application. They must make decisions regarding generator sizing, load types, whether generators should be paralleled, fuel storage, switching scenarios, and many other criteria.

Standby and emergency power systems provide power to ensure that life safety systems and critical equipment can operate during a power outage. NFPA 70: National Electrical Code (NEC) defines the categories that apply to generator power sources as emergency, legally required standby, optional standby, and critical operations power systems (COPS) systems. The differences among these systems are significant. In addition to the specific code requirements, design engineers as well as authorities having jurisdiction must know the effects these classifications have on how generators are applied within an electrical distribution system.

Due to the requirements of the NEC and NFPA 110: Standard for Emergency and Standby Power Systems, design engineers must carefully consider the implications of combining emergency, legally required, and optional standby systems to ensure code compliance with maintainability and economics in mind.

Learning Objectives:

  • Explain the applicable codes and standards: NFPA 70: National Electrical Code (NEC); NFPA 110: Standard for Emergency and Standby Power Systems; and other codes and standards as they apply to backup power systems.
  • Analyze and compare the differences and similarities among emergency, legally required standby, optional standby, and critical operations power systems (COPS) with a focus on backup systems.
  • Assess the effects each classification has on how generators are applied within an electrical distribution system to provide backup power.
  • Outline decisions regarding generator sizing, load types, whether generators should be paralleled, fuel storage, and switching scenarios.

Presenters:

Tom Divine, PE, senior electrical engineer and project manager, Smith Seckman Reid Inc., Houston

Douglas Lacy, PE, LEED AP, vice president, electrical engineer, WSP + ccrd, Dallas

Moderator: Jack Smith, Consulting-Specifying Engineer, Pure Power, and CFE Media, LLC



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me