Couplings for HVAC piping systems

Victaulic’s Style 107 QuickVic rigid couplings in 10- and 12-in. sizes are designed to expedite project construction by including no loose parts and no need to disassemble before installation.

11/11/2013


Victaulic’s Style 107 QuickVic rigid couplings in 10- and 12-in. sizes are designed to expedite project construction by including no loose parts and no need to disassemble before installation. Courtesy: VictaulicVictaulic’s Style 107 QuickVic rigid couplings in 10- and 12-in. sizes are designed to expedite project construction by reducing installation steps and requiring only standard hand tools for assembly. Installation-ready features include no loose parts and no need to disassemble before installation; the coupling is simply pushed onto the pipe-end as a fully assembled unit, joined by a second pipe-end and tightened. Installation is completed twice as fast as standard grooved couplings and up to 10 times faster than welding and flanging, while offering the same high-performance capabilities. No flame or heat is required for installation, improving jobsite safety. Ideal for HVAC, utility, and process piping applications, Style 107 rigid couplings are available in sizes ranging from 2- to 12-in., and join standard roll-grooved and cut-grooved steel pipe. The Style 107 family accommodates pressures ranging from full vacuum up to 750 psi (5,170 kPa), depending on pipe diameter and wall thickness. Couplings are supplied with a grade “EHP” EPDM gasket, which features a temperature range of -30 to 250 F. 

Victaulic

www.victaulic.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me