Cornell University—Stocking Hall Rehabilitation

Addition to existing building: Cornell University—Stocking Hall Rehabilitation; M/E Engineering, P.C.

08/09/2012


The Stocking Hall high-tech food research lab and dairy processing plant are shown.Project name: Cornell University—Stocking Hall Rehabilitation

Location: Ithaca, N.Y.

Firm name: M/E Engineering, P.C.

Project type, building type: Addition to existing building, research/lab/high-tech

Project duration: 7 years

Project completion date: Nov. 30, 2010

Project budget for mechanical, electrical, plumbing, fire protection engineering only: $25.6 million

Engineering challenges

Working in a campus environment where adjacent structures need to remain operational and be connected to the new building while construction takes place. This poses special challenges from a utility standpoint as well as a LEED standpoint.

Solutions

To meet the U.S. Green Building Council LEED requirements as well as Cornell's energy targets, a very aggressive approach to energy efficiency was taken. A number of strategies were incorporated, which included heat recovery on all the air systems, heat recovery on the water cooled condensing units to aid in the heating of outside air for laboratories, an aggressive demand control ventilation strategy that was utilized in the lab spaces, as well as utilizing relief air to assist with the ventilation of lab spaces and the 250-car parking garage.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me