Cooling towers and abatement system

The Marley NC Everest cooling tower is designed to deliver faster cooling than field-erected towers and constructed to withstand the rigors of power and industrial applications.

12/19/2016


The Marley NC Everest cooling tower is designed to deliver faster cooling than field-erected towers and constructed to withstand the rigors of power and industrial applications. Courtesy: SPX Cooling Technologies, Inc.The Marley NC Everest cooling tower is designed to deliver roughly 80% faster cooling than field-erected towers. It is specifically designed and constructed to withstand the rigors of power and industrial applications. The Marley Modular F400 cooling tower offers a modular construction process to speed field erection. Components of the cooling tower are pre-assembled at the manufacturing facility, and benefits of the tower include reduced laydown area, shorter construction schedule, and less impact from weather. Less manpower is required on site and assembly processes are safer. The Marley ClearSky Plume Abatement System is a fully integrated system that uses a series of PVC heat exchanger modules in the tower plenum to condense the moisture in ambient air before it exits the tower to reduce the visible plume. Instead of water vapor being released into the air, it is reclaimed and used in the cooling tower system.

SPX Cooling Technologies Inc.

www.spxcooling.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
January/February 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me