Cooling tower

The Marley NC Everest Cooling Tower is a cross-flow evaporative cooling system that provides up to 50% more cooling capacity than other single-cell, factory-assembled cooling towers.

04/13/2017


SPX Marley NC Everest Cooling TowerThe Marley NC Everest Cooling Tower is a cross-flow evaporative cooling system that provides up to 50% more cooling capacity than other single-cell, factory-assembled cooling towers. The NC Everest uses up to 35% less fan power to achieve higher energy savings. Its unique design minimizes piping and electrical connections to reduce installation costs. Seven-foot doors provide access to the tower’s interior service decks and mechanical components, making routine inspections and maintenance safer and easier. Featuring the patent-pending MarKey Drift Eliminators, the NC Everest Cooling Tower achieves the lowest measurable drift rate, down to 0.0005% of circulating waterflow, so less water escapes the tower.

SPX Cooling Technologies Inc., http://spxcooling.com

This product is a Finalist in the Consulting-Specifying Engineer 2017 Product of the Year program. View more Finalists and cast your vote at www.csemag.com/votepoy (voting closes June 30, 2017).



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me