Control valves for pressurized water reactors

Emerson Process Management received an $8 million contract to supply Fisher control valves for SCANA's nuclear generating stations in South Carolina.

08/19/2011


Westinghouse Electric Company has awarded Emerson Process Management more than $8 million in purchase orders for critical control valves to be used in two AP1000 pressurized water reactors at SCANA Corporation’s Virgil C. Summer Nuclear Generating Station in Jenkinsville, South Carolina. With site preparation already underway, construction is scheduled to begin late this year or early next year. The two new reactors are scheduled to begin commercial operation in 2016 and 2019, respectively.

Emerson was selected for this project based on its experience in producing valves for the same applications in other AP1000 plants. The Fisher control valves covered by the purchase orders are identical to those selected for the first four AP1000 nuclear power units being built in China and two additional units in the US Southeast.

Fisher air-operated control valves will serve as part of the safety-related system in the nuclear containment area. Engineered to comply with ASME Section III standards for components of nuclear facilities, they undergo rigorous qualification testing at the new Emerson Innovation Center in Marshalltown, Iowa. Valve actuators are sized in accordance with EPRI (Electric Power Research Institute) guidelines to ensure adequate operating margins that meet industry standards. They are also designed and tested to survive vibration loads of six times gravity in three axes to confirm they can operate after a seismic event.

For the passive residual heat removal system, Emerson developed a specially modified ball valve that meets all specified flow requirements and fits in the limited space available. These valves have received extensive testing to prove their ability to provide highly efficient flow through natural convection without assistance from the reactor coolant pump. Testing has also demonstrated tight valve shut-off when the plant is in operation to maintain efficiency and accurate throttling control for all flowing conditions.

www.emersonprocess.com 

Emerson Process Management



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me