Control system for modular boiler plants

AERCO Control System (ACS) is a flexible controller designed to maximize energy savings in modular boiler plants.

04/09/2012


The AERCO Control System (ACS) is a flexible controller designed to maximize energy savings in modular boiler plants. The ACS can stage and coordinate the operations of up to 32 boilers and is uniquely designed to maximize the operating efficiency of condensing equipment. Eight of these 32 boilers can be designated for domestic heating priority. Another eight boilers may be designated as swing boilers serving domestic hot water and building space heating as demand requires. With individual unit turndown as high as 20:1, a five-boiler plant delivers 100:1 system turndown when staged to operate sequentially. Able to regulate overall plant output with precise accuracy, a boiler plant with ±2 F header temperature variation is assured under normal load conditions. The ACS offers sequential or parallel operation flexibility, 100% control of auxiliary equipment, and user programmable modes of operation that can be changed in the field. It automatically rotates the lead unit to help equalize boiler runtime.

AERCO

www.aerco.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me