Condensing boilers

Condensing boilers to include three models with 750,000, 1.0 million, and 1.25 million Btu/hr inputs.

04/02/2015


Condensing Boilers to include three models with 750,000, 1.0 million and 1.25 million Btu/hr inputs.CREST Boilers are designed with a top-mounted micro-metal fiber burner, engineered specifically for fire-tube technology. The Wave fire-tube configuration creates turbulence as flue gas products flow down the tube, scrubbing the energy. As water flows up the vessel, super-heated flue products flow down the fire tubes. With one pass, heat is transferred and flue gases reach condensing temperatures. With an 8-in. touchscreen and multi-color interface, the SMART TOUCH operating system provides control and easy-to-use monitoring functions. The SMART TOUCH control can be integrated directly into a building automation system through BACnet, ModBus, and other communication protocols using a gateway device. Cascade sequencing can be programmed for lead-lag or efficiency optimized operation. Fire-tube technology also allows CREST boilers to operate over a wide range of flow rates with very low pressure drop, allowing for a full flow system. 

Lochinvar LLC

www.lochinvar.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me