Condensing boiler

Aerco expands its Benchmark family with the Benchmark 1.5 Low NOx condensing, fully modulating boiler.

04/01/2008


Aerco expands its Benchmark family with the Benchmark 1.5 Low NOx condensing, fully modulating boiler. WIth an operating range of 75,000 to 1.5 million Btuh, the boiler matches fluctuating loads to minimize boiler cycling and eliminate temperature overshoot. Designed with a small footprint, the boiler measures 79 in. H X 28 in. W x 36 in. D and is delivered in a single, fully assembled package that fits in a standard doorway. The model incorporates a stainless steel heat exchanger and Aerco's unit controller and air/fuel delivery system to deliver 20:1 turndown for maximized operating efficiency and seasonal fuel savings. The boiler is individually or in multiple unit designs. In addition to having a constant set point, indoor/outdoor reset schedule, or 4 to 20 mA signal, one or more boilers can be integrated via a Modbus communications protocol to Aerco's multiple boiler management system or facility-wide energy management or building automation system. An optional gateway to support BACnet, LonWorks, and N2 communications also is available.

www.aerco.com

Input #16 for Reader Service





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me