Condensing boiler, water heater

Laars' MagnaTherm is a 95% thermal efficiency modulating-condensing boiler or volume water heater that meets all ASME requirements and is AHRI certified.

04/21/2014


Laars' MagnaTherm is a 95% thermal efficiency modulating-condensing boiler or volume water heater that meets all ASME requirements and is AHRI certified. Courtesy: LaarsLaars' MagnaTherm is a 95% thermal efficiency modulating-condensing boiler or volume water heater available in 2, 3, and 4 million Btu/hr sizes. MagnaTherm offers a 5:1 turndown, small footprint, slim vertical design with removable top section, a stainless steel heat exchanger, and multiple voltage options to easily match building service. The MagnaTherm meets all ASME requirements and is AHRI certified. The boiler features an advanced VARI-PRIME pump control that seamlessly matches the boiler firing rate to pump flow, which reduces boiler pumping costs by up to 70%. The on-board control functionality balances combustion, airflow, and water flow to optimize boiler efficiency. Up to 8 MagnaTherms can be controlled in a cascading boiler bank. The system has a sealed condensate trap that does not need to be primed at start-up. It can accommodate up to 100 ft of vent and meets stringent NOx emission requirements.

Laars

www.laars.com 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me