Condensing boiler, water heater

Laars' MagnaTherm is a 95% thermal efficiency modulating-condensing boiler or volume water heater that meets all ASME requirements and is AHRI certified.

04/21/2014


Laars' MagnaTherm is a 95% thermal efficiency modulating-condensing boiler or volume water heater that meets all ASME requirements and is AHRI certified. Courtesy: LaarsLaars' MagnaTherm is a 95% thermal efficiency modulating-condensing boiler or volume water heater available in 2, 3, and 4 million Btu/hr sizes. MagnaTherm offers a 5:1 turndown, small footprint, slim vertical design with removable top section, a stainless steel heat exchanger, and multiple voltage options to easily match building service. The MagnaTherm meets all ASME requirements and is AHRI certified. The boiler features an advanced VARI-PRIME pump control that seamlessly matches the boiler firing rate to pump flow, which reduces boiler pumping costs by up to 70%. The on-board control functionality balances combustion, airflow, and water flow to optimize boiler efficiency. Up to 8 MagnaTherms can be controlled in a cascading boiler bank. The system has a sealed condensate trap that does not need to be primed at start-up. It can accommodate up to 100 ft of vent and meets stringent NOx emission requirements.

Laars

www.laars.com 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me