Compact, industrial Ethernet IO block

Turck BL compact on-machine, flexible block I/O simplifies communications for industrial Ethernet with analog, digital, thermocouple, RTD, serial, RFID, or a mixture of signal types in a compact, machine-mountable device.

12/27/2012


Turck BL compact on-machine, flexible block I/O for industrial Ethernet is a revolutionary I/O solution for collecting a variety of signals in one, rugged network node, the company said. Rather than routing all signals through a control cabinet, this device makes it possible to obtain analog, digital, thermocouple, RTD, serial, RFID, or a mixture of signal types in a compact, machine-mountable device over Ethernet.

Turck BL compact on-machine, flexible block I/O simplifies communications for industrial Ethernet with analog, digital, thermocouple, RTD, serial, RFID, or a mixture of signal types in a compact, machine-mountable device. Courtesy: TurckTwo signals types can be combined in any combination in BL compact, including, but not limited to, RFID and analog and digital and serial. BL compact may be customized to suit a user’s specific needs, allowing devices to be added to an existing network and signals gathered on the machine without an enclosure. This drop-in solution can be used to connect up to 16 devices, which significantly reduces the time it takes to run wires for each device back to the control cabinet and the potential for wiring errors.

“With the ability to employ two protocols in a single device, BL compact enables our customers to experience a more streamlined, simplified Industrial Ethernet solution,” said Chris Vitale, senior product manager, Turck. “This simplicity, combined with the flexibility to mix and match I/O types, allows their own end user base to efficiently satisfy diverse applications that may require different Industrial Ethernet protocols,” Vitale said.

BL compact is part of Turck’s unified Multiprotocol product portfolio, which enables users to employ one device for two Ethernet protocols, including EtherNet/IP and Modbus TCP. This simplifies operations by allowing multiple protocols to exist within one device, Turck said, yet only permits one Ethernet master to control the outputs while the input and diagnostic data is available to the other protocols. BL compact provides several I/O configuration options, including 16 M8 connectors for digital I/O with no splitters and an eight port M12 station for flexible operation.

BL compact is available with four, eight, or 16 ports in an environmentally rugged package that is rated for IP68 and IP69K protection. M8 or M12 connectors for bus communication and auxiliary power facilitate easy installation into any application, existing or new.

Turck provides sensing, connectivity and network products to help manufacturers improve their automated processes. The company will be an exhibitor at ProMat, Jan. 21-24, 2013.

www.turck.us 

- Edited by Mark T. Hoske, content manager CFE Media, Control Engineering, Plant Engineering, and Consulting-Specifying Engineer, mhoske@cfemedia.com.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me