Compact Ethernet switches for rugged applications

Rugged PoE Octopus switches by Belden require less space than switches with an external power supply and are easier to install and maintain.

02/17/2012


PoE Octopus switches by Belden require less space than switches with an external power supply and are easier to install and maintain. Courtesy: BeldenBelden Inc. (NYSE:BDC), has added six fast Ethernet switches to the Octopus range from its Hirschmann product series. The integrated power supply unit takes up less space than designs with an external power supply and require less cabling, which reduces possible error sources while increasing the operational reliability of the connected terminal equipment.

Three of the switches are unmanaged 10-port devices. The others have nine ports and feature Hirschmann’s Layer 2 basic software, which incorporates a variety of management and security functions and fast redundancy methods. Both the 9-port and the 10-port switches are available with or without Power over Ethernet (PoE) functionality and have a 24 V or 110 V power supply unit. The PoE versions are fanless with additional cooling fins that provide effective temperature management resulting in longer lifecycles.

All six switches have robust, compact die-cast zinc housings and are designed to operate at temperatures in the range of -40 C to +70 C. They also fulfill the EMC and fireproofing requirements of the European standards that govern use in rail vehicles.

The switches measure 184 x 189 x 70 or 184 x 272 x 77 mm (width x height x depth), depending on the design, and can be mounted on a wall or directly on a machine. Their protection ratings are IP67 (9-port version) and IP54 (10-port version) and they also feature a high level of EMC and vibration resistance. The Fast Ethernet ports (10/100 BASE-TX) have D-coded M12 connections. The PoE feature supplies 15 W per connected terminal device, using the phantom power method in which the terminal equipment is powered via the same wire-pair that carries the data. This means that two-pair cabling systems can also be used. The front of the unit has LEDs that display device status and network status as well as correct function of the power supply.

The managed designs can be configured via an Ethernet interface using command line interface (CLI), DHCP relay agent option 82, HiDiscovery or V24 interface, or via the ACA11 autoconfiguration adapter. RMON, port mirroring and LLDP (Topology Discovery 802.1ab) are available for diagnostic purposes. Alarms are connected via an additional signaling contact. SNMP V2c and V3 are also supported. Redundancy methods such as HIPER Ring, MRP and RSTP ensure a high level of network availability. The supported security mechanisms include IP and MAC port security, SNMP V3, SSH V3, SNMP access settings (VLAN/IP) and access control via IEEE 802.1x.

Belden Inc.

www.belden.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com 

More network technology: controleng.com/networks



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me