Communicating wirelessly with CAN networks

CiA has been developing new methods for improving communication through remote and wireless technologies.

10/05/2011


For several years, some vendors have provided CAN gateways with wireless links, especially those with Bluetooth applications. Therefore, devices connecting CAN and wireless networks have become standard for CiA members and technicians. The CiA 812 application note describes use cases for CiA 457 compliant gateways. The CiA 457 CANopen gateway profile specifies the wireless communication links. This includes configuration parameters and diagnostic as well status information. The profile supports Bluetooth, WLAN, and proprietary solutions. In typical applications single or multiple sensors are connected wireless to the CANopen network or remote radio I/O modules control the mobile machinery (e.g. crane and other construction machines). Those user panels are equipped with joysticks, pushbuttons, and other I/O elements. If the wireless connected modules are CANopen devices, a tunneling of CAN messages interpreted as CANopen protocols as specified in CiA 315 is reportedly possible. "Since August, CiA has released internally the CiA 315, CiA 457, and CiA 812 documents, which allow a flexible usage of wireless communication links in a CANopen system," said Holger Zeltwanger, CiA Managing Director. "Especially in mobile machines this will simplify system design of heterogeneous network architectures." The system integrator also should refer to the CiA 302-7 bridge-/router specification, in which the Remote SDO and Remote EMCY protocols are defined.

www.cia.org 

CAN in Automation

- Edited by Chris Vavra, Control Engineering, www.controleng.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me