Commercial rooftop ventilator

ecoPowerHybrid combines gravity and motorized ventilation and is based on a turbine that offers high cfm with flat rainproof hats while giving free airflow caused by wind, hot air, or both.

01/26/2016


ecoPowerHybrid combines gravity and motorized ventilation and is based on a turbine that offers high cfm with flat rainproof hats while giving free airflow caused by wind, hot air, or both. Courtesy: EdmondsUSAEdmondsUSA's ecoPower Hybrid is a hybrid commercial rooftop ventilator that combines gravity and motorized ventilation and is available with 16-, 24-, and 36-in. diameter throats. It is based on a turbine that offers high cfm with flat rainproof hats, which gives free airflow caused by wind, hot air, or both. The EC German motor offers high airflow while using low power. ecoPOWER has an efficient cfm-to-watt ratio that reduces when aided by wind: EP400 (16-in.) 1400-cfm at 68 W, EP600 (24-in.) 2519-cfm at 106 W, EP900 (36-in.) 5885-cfm at 260 W. The rooftop ventilator is used for cooling warehouses, schools/universities, wastewater treatment plants, and other types of buildings.

EdmondsUSA

www.edmondsusa.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me