Commercial rooftop unit

The Rebel commercial rooftop unit system from Daikin McQuay functions as a VAV heat pump unit down to 3 tons.

03/07/2012


The Rebel commercial rooftop unit system from Daikin McQuay functions as a variable air volume (VAV) heat pump unit down to 3 tons. In addition, the Rebel is uses variable heat pump technology with hybrid (gas, electric) heat options, variable electronically commutated motors (ECM) fan motors, and Daikin’s advanced variable inverter scroll compressor. When functioning as a VAV unit, Rebel allows for better comfort control. The motors used on all fans are variable speed ECM, which reduce noise, providing ultra-quiet operation for building occupants, while inverter compressor technology delivers unbeatable efficiencies. The Rebel unit will be available in 3- to 15-ton sizes and offers a modulating hot gas reheat option that contributes to efficient operation in colder weather climates, unlike other rooftop heat pump units. These benefits help make this energy-efficient unit ideal for low-rise commercial buildings such as schools or office buildings and as a dedicated outdoor air system that provides make-up air for 100% outdoor air applications.

www.mcquay.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me