Combining Corporate-Wide Security

When Minneapolis-based Ceridian, the second largest payroll processor in the United States, implemented its move to a new, company-owned headquarters, company officials prioritized parking ramp security, life safety and corporate-wide access control. Life safety Ceridian's new five-story, 260,000-square-foot headquarters utilizes a security and life-safety system that integrates a broad range ...

07/01/2001


When Minneapolis-based Ceridian, the second largest payroll processor in the United States, implemented its move to a new, company-owned headquarters, company officials prioritized parking ramp security, life safety and corporate-wide access control.

Life safety

Ceridian's new five-story, 260,000-square-foot headquarters utilizes a security and life-safety system that integrates a broad range of security options: subsystems for access control, intrusion detection, fire alarm/life safety and closed-circuit television (CCTV), as well as digital badging, intercom, paging and sound. Individual systems are linked to a common database and conveniently displayed.

Security had to be arranged for internal, entrance and exit doors and for a sizable parking ramp. Security concerns—intruders in the building, minor thefts and assaults—had been escalating in the old headquarters. Consequently, the goal was to design the new building to avoid such problems from the start.

CCTV and access

Parking-ramp security arrangements included fixed cameras at entrances and complete pan, tilt and zoom coverage of each corridor of the ramp. Camera coverage was carefully checked to ensure that there were no blind spots, and emergency call boxes were also provided. The CCTV is monitored around the clock.

Building-wide, some 20 doors are provided with access control. Ceridian subscribes to a philosophy of an open work environment to encourage shared work arrangements and collaboration. This is carried out within the new corporate headquarters, where only a few high-vulnerability areas like the local-area network (LAN) room, telecommunications closets and payroll operations are not accessible to every employee.

The building is fully sprinklered and protected with a fire-detection/voice-evacuation system that is integrated with the security system. Application-specific smoke detectors are highly resistant to false alarms—a major consideration for Ceridian's security group, which had formerly been plagued with unwanted alarms. Laser-beam smoke detectors at two levels monitor the building's five-story atrium. To add visual information to the signals and intelligence provided by the detectors, the life-safety system is tied into the CCTV network.

Remote locations

A major consideration in the selection of the system was its ability to provide remote networking control, simultaneously monitoring multiple assets through a portal. Access control for all major U.S. sites is managed from corporate headquarters through the integrated security and life-safety system. Well before the move, the headquarters security group began bringing the eight remote locations on-line. The first remote location—Boston—was started up in 1999.

The networking program was one of the most complex tasks in the installation. The Minneapolis LAN was Ethernet-based, two New Jersey sites were token ring and the rest utilize dial-up connections.

As a convenience, the dial-up sites can also be disconnected for stand-alone operation. Local panels store information until their memories are full, then they are reconnected for updating and maintenance.

In the future, the security group would like to monitor all smoke and fire alarms from the central Minneapolis location, just as it presently does with access control. Also on the wish list is substituting digital recording for tape as the technology matures.





Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me