CMMS contributes to total productive maintenance initiatives

03/14/2012



When a manufacturing organization embarks on a total productive maintenance (TPM) project, especially maintenance operations, it is critical to get the feedback from any/all people impacted, down to machine operators. So often we hear about utopian desires from upper management related to maintenance operations.

TPM would be much more successful if people working “in the trenches” are included in the design, implementation and intended outcomes of the project. This stretches way past the maintenance staff to equipment operators themselves who could be “deputized” to handle elementary quality control and preventive maintenance tasks.

CMMS should be the operations management, planning, analysis and audit technology component of any plant TPM strategy. CMMS tracks and analyzes production equipment based on maintenance and repair history, etc. It also identifies and manages the work load of the people involved in the maintenance process.

An example: an asset could be actively “PM’d” by a combination of people – dedicated maintenance technicians as well as equipment operators. CMMS easily identifies and analyzes these efforts – both from an operations management and a historical analysis perspective.

TPM starting point? CMMS

CMMS also makes a good starting point for any TPM project by supporting universal maintenance goals: achieving optimal performance, longevity and safety of production and utility equipment. Start by entering each system into CMMS to automate ongoing monitoring, and corrective, preventive and predictive actions for each system.

CMMS captures asset information, work order history, purchase order and invoice information for outsourced repairs, of all current and new equipment. It “pieces together” the history of equipment failures, and analyzes and reports on what needs servicing, by when, and then populates preventive maintenance schedules with the historical data. CMMS helps identify problem areas in a facility and analyzes the effectiveness of a TPM deployment.

For example, a new building was being added to a large facility in South Carolina. During construction the maintenance operations team entered all new equipment data into its CMMS system vs. adding information once the construction project was completed.

Based on similar equipment being used in its larger facility that CMMS was tracking, the team set up a maintenance forecasting system and future PM schedules for new building equipment. PM alerts were set up in advance to notify maintenance to replace parts, or plan for more maintenance resources. This model should be applied to any TPM project.

Measuring the value of TPM

Being able to measure TPM initiatives is important for making process improvements. CMMS does a good job of measuring asset effectiveness and people effectiveness through monitoring, analysis, auditing and providing related information that is typical for any organization deploying a TPM strategy. CMMS is at the heart of effective maintenance operations – from upper management all the way to asset operators.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me