Choose the right industrial connector

Evaluate application and environment to determine the best connector to incorporate into an industrial design or upgrade.

06/07/2012


Mencom Corp. offers industrial Ethernet connectors. Courtesy: MencomDetermining the connector to incorporate into an industrial design or upgrade is simply a matter of evaluating the application needs and environment. Start by asking yourself, “What type of transmission do I need?” and “What are my environmental conditions?”

Are your connection points needed for power, communication, signaling, or a combination? This is your first variable. What is your transmission requirement? Then determine the number of contact points needed, the current (amperage) requirements of the application, and the space constraints, if any. And, if using a heavy-duty rectangular connector, determine the wire termination method for the contact pins (spring, clamp, or screw). For many power (under 15 amps), signaling, and communication applications requiring fewer than 20 contact points, an overmolded circular connector offers a durable, economical, and reliable solution. Connector solutions requiring higher current carrying capacity or a greater pin count can often be found with a heavy-duty rectangular connector.

When the application calls for communication via an industrial protocol, specific network cordsets can be used. Whether using DeviceNet, Profibus, industrial Ethernet, Foundation Fieldbus, or one of many other protocols, each has its own connector design and often a specialized wiring code.

The application environment is also very important in determining what connector to choose. This factor will dictate what cable jacket should be used when considering a molded cordset. If the application is such that the cable needs to be protected from weld slag, TPE might be the best choice. If lubricants and coolants are prevalent, PUR would work. An application with continuous movement may require a cable with a high flex rating. Most standard applications can be addressed with a simple PVC jacketed cable. Selecting the correct cordset for the environment in the beginning can save money and time in the long run, by avoiding unneeded downtime, troubleshooting, and premature replacements.

Mencom Corp. offers cordsets for specific industrial protocols, such as DeviceNet, Profibus, industrial Ethernet, Foundation Fieldbus, and others. Courtesy: MencomUsing high-quality overmolded cordsets, and the proper mating receptacles, an IP67 rating can be achieved to accommodate various industrial environments. IP67 indicates that a connector is protected from dust and will withstand being immersed in water for a limited amount of time. This rating is sufficient for most industrial applications.

For wiring machines and system controls, legacy standards such as the MIN family of circular connectors still prevail as do the hard-to-match rectangular connectors. After evaluating power needs and environment, your choices are usually clear. When we include network configurations, the options expand to include bus networks and Ethernet. Micro-connectors for each of these formats are easy to find. Keep in mind that all connectors are not equal. Quality of components leads to reliability. At the end of the day, systems are only well connected when they’re running.

- Lynne Keener is marketing coordinator for Mencom Corp. Edited by Mark T. Hoske, content manager CFE Media, Control Engineering, Plant Engineering, and Consulting-Specifying Engineer, mhoske@cfemedia.com.

www.mencom.com 

ONLINE extra -  Founded in 1987, Mencom Corp., located in Oakwood, Ga., provides industrial electrical connectors. Mencom is among the last remaining manufacturers of U.S.-made electrical cordsets, Keener said. 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me