CDM Smith: University of Connecticut, On-Call MEP/Life Safety & Fire Protection, Cooling Tower

Electrical, power; fire, life safety; cooling tower; and system replacement

08/09/2018


A slightly more distant exterior view, looking west, which shows the proximity of the neighboring apartments.Engineering firm: CDM Smith

2018 MEP Giants rank: 63

Project: University of Connecticut, On-Call MEP/Life Safety & Fire Protection, Cooling Tower

Location: Stamford, CT, United States

Building type: Cooling tower

Project type: System replacement

Engineering services: Electrical, power; fire, life safety

Project timeline: April 2015 to July 2018

MEP/FP budget: $118,715

 

Challenges

CDM Smith faced issues with existing infrastructure and acoustics (noise). The campus operates awater-cooled chilled water system thatserves the HVAC system in the building at One UniversityPlace. The two-cell cooling tower, which provides heat rejection for this system, was near the endof its useful life. CDM Smith investigated tower replacement options to ensure the system continuesto operate reliably. The sound produced by the tower installation was a significant factor in determining the course ofaction for two reasons:First, Code dictated a maximum allowable generated noise level, aboveambient, that could be present at the property line. Second, the University desired to minimize theacoustic impact on the apartment building which sits adjacent to the tower installation.

Exterior side view, looking west.Interior view looking up under the two cooling tower fans.An exterior view looking northwest. This is the air inlet side of the tower, which faces away from the apartments.

Solutions

CDM Smith worked with an acoustic consultant to measure ambient sound levels as well as the sound levels produced by the existing towers. This data noise level was used as a baseline noise level for the selection, installation and control strategy of the new towers. The replacement equipment was a cross-flow cooling tower with ultra-quiet propeller fans and acoustical discharge extensions on the fans. The selected model was only open on one side. Therefore; there was no direct sound path from the cooling tower to the adjacent apartment complex. The project resulted in a tower installation,which is 5 to 9dB lower than the ambient noise level and uses less fan energy than the original equipment. The construction process was phased to ensure that the continuously operating chilled water system without any outages.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me