Case study: Royal Society for Prevention of Cruelty to Animals (RSPCA)

Animal facility saves water via a variety of methods.

07/21/2016


Figure 1: This image shows the first stage of the reedbed treatment system at the RSPCA. The stainless steel bag filters located centrally in the photo remove the pet hair from the incoming wastewater to prevent blockages. The vegetation and media concealThis project was small and had a number of fascinating aspects that added great interest for the team as designers. As part of an expansion and refurbishment of the facilities at the Royal Society for Prevention of Cruelty to Animals (RSPCA) Burwood site in Melbourne, Australia, and due to a long-running drought through Southeastern Australia, they decided to implement some water-saving strategies (see Figure 1).

As part of statewide water restrictions, irrigation of landscape areas was restricted, so the initial brief from the client was to provide a source of water for irrigation of a landscaped area. Their initial thoughts were that the irrigation would come from rainwater collected onsite. However, after looking at the daily rainfall figures and performing water balance for their complete operations, it was clear that while the rainwater-collection tanks may be overflowing in winter, this approach could not provide the irrigation water they needed during the summer months.

It also became apparent through metering that they were using large amounts of water for a daily washdown of the kennels and other facilities within the site. As part of a broader overall water sustainability plan that included installation of low-flow fixtures and submetering of major water uses, a strategy was developed to reduce the overall water use and make double use of the landscaped area: to provide both a lush green landscape area and treat the washdown water to allow reuse for kennel washdown the following day.

This was achieved through the installation of low-flow high-pressure sprayer nozzles for the kennel washdown to reduce water use and the use of a multistage passive vertical flow reed bed system integrated into the landscape for treatment of the washdown water prior to reuse. Because the site is on a slope, pumping is minimized by moving the water through the system and between stages using dosing siphons. Buildup of total dissolved salt caused by the constant recirculation and reuse of water is managed by bleeding a portion of the treated water from the system to the sewer and replenishing with rainwater supplies.

The water cleaned through the reed bed system is disinfected using ultraviolet (UV) and chlorination to remove pathogens prior to reuse. Excess rainwater is used in the building for toilet flushing. This project illustrates an integrated approach to water use across the site. The scheme was completed in 2013 and saves approximately 1,600 gpd or 584,000 gallons/year in water use, not including the irrigation requirements avoided by installation of the green landscaped reed bed areas and the low-flow fixtures.


Peter Harbour is a senior scientist at CJ Arms and Associates.

Robyn Overall is water sustainability scientist at CJ Arms and Associates.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me