Case study: RMIT Design Hub

University achieves water-sustainability goals.

07/22/2016


Figure 4: This photo shows the active facade of the RMIT Design Hub building. The movable glass disks pivot to either shade or allow sunlight to reach the building to help maintain indoor temperature conditions, thereby reducing energy and water use for hThe RMIT University Design Hub was developed in Melbourne, Australia, to support the university's position as an internationally renowned leader in design education and research and encourage industrial collaboration (see Figure 4). Water sustainability was intrinsic to the building design, with an integrated rainwater collection scheme collecting rainwater from the main building roof as well as the expansive forecourt area. An analysis of the water demands for RMIT Design Hub identified that toilet flushing is the highest portion of the demands (44%) and the greatest opportunity for water savings. Therefore, the reclaimed water is treated and reticulated throughout the building for toilet flushing.

The stormwater runoff from the forecourt area is passively treated through media filtration at the source, eliminating the need for a mechanical plant, reducing the overall energy demand, and providing water suitable for toilet flushing. The building includes provision for connection to an external precinct-wide recycled water system as well as provision for exporting wastewater if required, providing the facility with flexibility and future integration within the wider precinct and RMIT campus. These measures provide average water savings of 268,000 gallons per year. The water-sustainability initiatives have been an integral part in the facility being awarded a 5-star Green Building Council Australia Green Star building rating.


Peter Harbour is a senior scientist at CJ Arms and Associates.

 

Robyn Overall is water sustainability scientist at CJ Arms and Associates.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me