Capture waste heat: energy-efficiency directive

A proposed Energy Efficiency Directive is set to make energy generation from waste plants more efficient by making combined heat and power (CHP) with district heating the default option.

06/27/2011


According to edie, The European Commission (EC) is proposing that all new and refurbished thermal electricity generation facilities should be fitted with high efficiency heat recovery equipment. Through encouraging siting of generation stations near to sites of heat demand, the directive aims to exploit cogeneration opportunities as a key mechanism for increasing energy efficiency across the EU.

The EC also suggests that CHP electricity should benefit from priority grid access and dispatch to bring it on par with electricity from other forms of renewable generation. Commenting on the proposals, director of the Combined Heat & Power Association, Graham Meeks, said they were "a step in the right direction". "Energy-efficient solutions are among the most cost-effective ways of reducing emissions, and this directive seeks to drive a step-change in energy efficiency across the EU," he said.

The directive would also require member states to establish national plans for district heating and cooling and that this should be incorporated into local spatial plans to coordinate the deployment of heat loads close to the point of demand. Member states would facilitate the development of district heating and cooling infrastructure to exploit CHP opportunities as well as the capture of surplus heat from industrial processes.

The EC suggests that these proposals will overcome the barriers to CHP that the Cogenerative Directive and the EU Emissions Trading Scheme have so far proved ineffective in tackling. Between 2004 and 2008, the share of electricity from CHP in the EU only increased from 10.5% to 11%. The new directive's proposals for CHP alone are projected to save up to 25M tonnes of primary energy and 55M tonnes of CO2 emissions per year from 2020.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me