California Building Code changes take effect

On Jan. 1, California will see the introduction of the first Green Building Standards Code in the nation.

01/01/2011


Linda Williams, of The Willits News, explains what 2011 has in store for California's Green Building Codes.

A series of changes to the California Building Code go into effect Jan. 1. This represents about 200 pages of new state code.

The changes introduce the first-in-the-nation Green Building Standards Code, or CALGREEN. This new code is expected to make new buildings more energy efficient and environmentally responsible by reducing energy, waste and water use. While these code changes apply as a minimum to all new buildings within California, more restrictive local codes may apply.

The new CALGREEN standards include a mandatory 20% reduction in indoor water use for residential and nonresidential buildings. While the California Building Code also sets a maximum water use allowed for separate fixtures, such as shower heads and toilets, the CALGREEN standard then requires the building must use 20% less than the sum of the maximum allowed for each fixture.

The new standard requires a 50% reduction in landfill disposal of construction and demolition debris. A construction waste management plan is required to identify the materials to be diverted for recycling, reuse or salvage. It must also specify which materials will be presorted at the construction site and which will be comingled. It should identify the diversion facility and the construction methods employed to reduce the amount of waste generated. This must be documented to the waste management authority.

Building inspectors are now authorized to examine the buildings, structures or sites applying for a building permit prior to issuing a permit.

Storm water drainage and retention during construction which disturbs less than an acre of soil shall "manage storm water drainage during construction."

Other changes require the installation of automatic fire sprinklers for all one and two family dwellings. Carbon monoxide alarms must now be installed in dwelling units and in sleeping units which have either fuel burning appliances or attached garages. At least one electrical outlet is now required for each balcony, deck or porch. All 120 V circuits with receptacles within a residence will now require arc-fault circuit interrupter protection. All dwelling unit receptacle outlets shall be tamper resistant receptacles.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me