Cable tray system

The Redi-Rail cable tray system by Cooper B-Line features an I-Beam side rail design, which reduces design time, installation cost, and procurement costs.

04/08/2013


Redi-Rail cable tray system by Cooper B-LineThe Redi-Rail cable tray system by Cooper B-Line features an I-Beam side rail design, which reduces design time, installation cost, and procurement costs. The system also utilizes the efficiency of the I-Beam shape along with the strength and corrosion resistance of Aluminum 6063-T6 material. This makes the Redi-Rail system easier to cut, handle, and install while still maintaining a NEMA 12B load rating. The Redi-Rail system has also optimized the location of the pre-punched rung and splice holes. The holes are positioned at the top and bottom of the I-Beam web. Because they are mechanically fastened, each rung can be moved or removed for precise cable dropouts.

Cooper B-Line

www.cooperbline.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me