Bypass/isolation switches

Russelectric RTS Series Bypass/Isolation Switches combine an automatic transfer switch with a manual bypass/isolation switch that allows the transfer switch to be isolated for inspection, maintenance, repair, or testing.

07/22/2010


Russelectric RTS SeriesRusselectric RTS Series Bypass/Isolation Switches are UL labeled and listed for 30-cycle closing and withstand ratings based on testing per UL Standard 1008.  Available in continuous current ratings from 100 to 3000 amps, these switches dramatically simplify the selective coordination of overcurrent devices in backup power systems for healthcare and other mission-critical facilities.

The 30-cycle rating of Russelectric RTS Series Bypass/Isolation Switches allows downstream overcurrent protective devices to clear a fault before upstream devices.  Consequently, they greatly simplify the engineering task of selective coordination mandated by the National Electrical Code for emergency and legally required standby systems. 

For more information, visit www.russelectric.com.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me