Biomass power plant deploys wireless instrumentation for predictive maintenance

Enomondo S.r.l. uses new field instruments to extend its visibility into a new boiler and complex fuel pre-treatment operation.

03/27/2013


The 13.7 MW power generating plant is located at the Caviro Distillerie wine and denatured alcohol plant. It uses 140,000 metric tons per year of by-products from the alcohol production process to produce power for 29,000 neighboring households. Enomondo – a partnership between Caviro Distillerie and Herambiente – is using Emerson Process Management’s Smart Wireless devices to monitor a complex fuel pre-treatment operation, an incineration process, and a new boiler at its biomass power plant in Faenza, Italy. Wireless technology has enabled additional measurement devices to be installed quickly and easily, helping to optimize control of the process and contributing to an estimated 5% increase in overall operational efficiency. The availability of diagnostic data has also improved predictive maintenance procedures.

The 13.7 MW power generating plant is located at the Caviro Distillerie wine and denatured alcohol plant. It uses 140,000 metric tons per year of by-products from the alcohol production process to produce power for 29,000 neighboring households. This use of alternative fuels helps to reduce Italy’s power generation CO2 emissions by 35,500 tons a year.

To increase the plant’s efficiency and capacity, Enomondo installed a new boiler, which created the need for new instrumentation for monitoring temperature and pressure. In addition, the existing fuel pre-treatment process, which ensures nitrogen oxide emissions are less than half the levels set by Italy’s Integrated Environmental Authorization, involves numerous variables that are not easily controlled and would benefit from additional measurement points.

A group of 22 Smart Wireless transmitters, including Rosemount 3051S pressure and 648 temperature instruments, transmit measurement data via a wireless gateway into the existing Emerson DeltaV digital automation system.To meet these needs Enomondo chose Emerson’s Smart Wireless technology, which offered simpler installation and lower overall costs than traditional wired solutions. A group of 22 Smart Wireless transmitters, including Rosemount 3051S pressure and 648 temperature instruments, transmit measurement data via a wireless gateway into the existing Emerson DeltaV digital automation system, giving operators greater visibility into the process so that they can make adjustments to increase efficiency.

As a result, Enomondo has been able to increase operational efficiency and improve output. Installation, maintenance and operating costs have also been reduced. The company says installation was very easy and required no external engineering capability. Because the wireless instruments required no cabling or cable ducts, infrastructure costs were around 30% lower than a wired alternative. Layout and wiring costs were halved, and installation and instrumentation control costs reduced by 40%.

Using the existing DeltaV system and AMS Suite predictive maintenance software to receive, store, and analyze device data, Enomondo has been able to use the wireless system to meet its predictive maintenance requirements. The additional continuous data made available by the wireless network enables personnel to identify performance degradation trends that signify potential problems, then use this information for better maintenance scheduling that helps optimize operator efficiency.

Because the wireless instruments required no cabling or cable ducts, infrastructure costs were around 30% lower than a wired alternative. Layout and wiring costs were halved, and installation and instrumentation control costs reduced by 40%. "The modularity of Emerson’s Smart Wireless technology, the ease and reduced cost of implementation compared to wired devices, and its reliability once installed have encouraged us to expand its use into other applications," said Alessandro Catani, Enomondo plant and energy manager. "For example, temperatures in some of the air-conditioning systems at the plant were prone to overheating. By installing Rosemount wireless temperature transmitters on a temporary basis, it was possible to obtain the data we needed to identify potential problems and correct them."

The alcohol storage tank farm at the Caviro Distillerie production facility has added 26 Rosemount inventory tank gauges with Smart Wireless THUM Adapters to monitor levels continuously and increase safety by preventing overspills.

Caviro

www.caviro.it

Emerson Process Management

www.emersonprocess.com

Edited by Peter Welander, pwelander@cfemedia.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me