Best practices for mixed-use buildings: Sustainability, energy efficiency

Taking on a mixed-use structure—such as one that includes retail and residential portions—can be an engineering challenge. With all the different engineered systems involved, it can be like working on and integrating several different projects at once. Energy efficiency, sustainability, and green buildings are discussed.

09/29/2014


Anil Ahuja, PE, RCDD, LEED BD+C, CxA, President, CCJM Engineers Ltd. ChicagoJason R. Gerke, PE, CxA, LEED AP BD+C, Mechanical and Plumbing Team Leader, GRAEF, MilwaukeeKeith Lane, PE, RCDD, NTS, RTPM, LC, LEED AP BD+C, President/CEO, Lane Coburn & AssociatesBrian A. McLaughlin, PE, Associate, Arup, Los Angeles

Respondents

  • Anil Ahuja, PE, RCDD, LEED BD+C, CxA, President, CCJM Engineers Ltd. Chicago
  • Jason R. Gerke, PE, CxA, LEED AP BD+C, Mechanical and Plumbing Team Leader, GRAEF, Milwaukee
  • Keith Lane, PE, RCDD, NTS, RTPM, LC, LEED AP BD+C, President/CEO, Lane Coburn & Associates, Bothell, Wash. 
  • Brian A. McLaughlin, PE, Associate, Arup, Los Angeles

CSE: Many aspects of sustainability (power, HVAC, maintenance, etc.) require building personnel to follow certain practices to be effective. What, if anything, can you as an engineer do to help increase chances of success in this area?

Gerke: The most important item to consider, after meeting the owner’s project requirements, is to make sure to keep things simple. There is an acronym called KISS (“Keep it simple, stupid”), which many people have heard of. A small effort in the design phase of making sure the filters are similar sizes or types for a hundred units is a very basic strategy, but can save many hours in labor and reduce replacement stocking requirements over the entire life of the systems. Other concepts include setting up the unit configurations in a similar fashion throughout the building so that when maintenance personnel are familiar with one unit, they are automatically familiar with most of the equipment. Also, working with the electrical engineer on the project to circuit equipment in similar ways and to similar locations will reduce time spent identifying where and how equipment is served from power panels when shutdowns need to occur.

Ahuja: Increase the amount of training hours required; provide as much backup documentation to the staff as possible; and ensure proper commissioning of systems, maintaining records, and regular maintenance of systems.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me