BAS motor controls with auto run, predictive calibration

The BAS motor controls from Cerus Industrial accept dry voltage inputs and include other options like auto run and predictive calibration. One model accepts up to 600 V AC and motor loads up to 40 A.

11/27/2012


The BAS motor controls from Cerus Industrial accept dry voltage inputs and include other options like auto run and predictive calibration. A single model accepts up to 600VAC and motor loads up to 40A. Courtesy: Cerus IndustrialThe BAS motor controls from Cerus Industrial incorporate the company’s Smartstart Control Module for seamless integration with digital controls. The starters accept dry voltage inputs (wide range 12 V ac-250 V ac) for activation by control systems without interposing relays. Other control options include auto run, fireman’s override, fault, proof of flow (detects loss of load), and SmartStart predictive calibration (fault alarm). Integrated LED pilot lights and Hand/Off/Auto keypad are standard, simplifying unit setup and verification.

A single model accepts 208-600 V ac and motor loads up to 40 A, eliminating discrete thermal overloads and numerous contactor coil voltages typically required with other motor starters. The broad operating ranges enable distributors to eliminate thousands of dollars on unnecessary stock and mis-sizing issues. 

Upon motor start-up, the electronic Smartstart overload allows the starter to look for a safe operating range based on motor starting current. If the starter isn’t calibrated within that range, an alarm is activated and the starter contactor is opened. This feature is meant to protect against operators increasing the overload to overcome motor jams or other impedances and to provide base line protection should the starter not be calibrated. The BAS with Smartstart also protects against locked rotor, stall, and other undesirable starting conditions.

Cerus Industrial

www.cerusind.com 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me