Baring their Teeth: Dental Care for Animal Patients

Animal dental treatment is a relatively new field of practice, and while many hospitals do not have full-time dentists on staff, more stand-alone clinics are being built. Dental treatment rooms generally have a tub table for carrying out procedures, with hot and cold potable water and connections for compressed air, vacuum and oxygen.

10/01/2000


Animal dental treatment is a relatively new field of practice, and while many hospitals do not have full-time dentists on staff, more stand-alone clinics are being built. Dental treatment rooms generally have a tub table for carrying out procedures, with hot and cold potable water and connections for compressed air, vacuum and oxygen.

Dental procedures on animals differ from those for humans: The patient is completely anesthetized and the doctor must move around more because of the anatomy of animal mouths. Thus, medical gases must be available but from hoses that are thoughtfully located so as not to disturb the doctor. A good practice is to provide ceiling-drop outlets for oxygen and vacuum to minimize dangling hoses between the walls and the respirator.

The Rosedale Animal Dental Center in Baltimore, Md., is a one-of-a-kind facility comprising a veterinary hospital, an animal dental clinic and a dental teaching center under one roof. The dental suite consists of a tub table and a standard surgical table; 1/2-inch domestic cold and hot water are connected to the tub table. A standard kitchen sink with a gooseneck and a plaster solids trap is located on the counter.

Usually, two patients are taken care of simultaneously, so oxygen and vacuum piped above the ceiling are dropped along a column between the two tables to twin outlets for easy access. Compressed air is also piped above the ceiling and drops down to the dental tool rack, which swings along a hinge. An oil separator is installed in the compressed-air line ahead of the tools. Filtered water is used to power tools without clogging.

At the core of the facility is a dental training classroom with 13 working benches and a service counter. Compressed air is piped to each training bench from an air compressor dedicated to the training area. Vacuum, however, is piped throughout the facility and is served by one pump. A countertop sink with a plaster solids trap is installed in the classroom.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me