Avoid Sweating Slab Syndrome to keep workers safer

Autumn temperature swings can lead to condensation, and safety concerns.

10/03/2012


Sweating Slab Syndrome, which often occurs during periods of high condensation during the Spring and Autumn, can be dangerous for workers if not properly addressed. Courtesy: Big Ass FansSpring and fall herald pleasant weather in many areas, with warm days and cool nights. However, the same combination that makes outdoor activities pleasant can wreak havoc in industrial facilities. Temperature and humidity swings create condensation on concrete slab floors common in many industrial settings. Known as “sweating slab,” this sheen of water can cause big issues with employee safety and product integrity.

Following are a few of the common questions about sweating slab, and an example of a company that successfully solved its perspiration problem. 

What is sweating slab?

Condensation occurs when warm, moist air contacts a cold surface. As the air becomes colder, it loses its ability to store moisture. In the spring and fall, temperature swings and the accompanying condensation on concrete floors can cause problems in workplaces worldwide, resulting in serious worker risk, operational issues and product loss.

According to Peter Craig, founder of Concrete Constructives, “the two major causes of slab surface sweating are classic dew point and hygroscopic activity outside of classic dew point parameters.” 

Hygroscopic activity involves substances, particularly soluble salts, in and on the surface of the slab drawing moisture from the air to the surface of the slab. Dew point related issues occur when the surface of the concrete slab is at or below the saturation point of the air.  In the spring, a concrete slab will trail the air temperature by about a month. So while the April air is a balmy 72, the slab might still be stuck in March at 50 F. Warm air sits on this cold slab, dropping moisture as it cools. 

What safety issues are caused by sweating slab?

Both foot and forklift traffic can become perilous when the surface is slippery. While many warehouses endeavor to create smooth floor surfaces for efficient movement, having a smooth floor can compound the effects of seasonal condensation.

According to the National Floor Safety Institute, the majority of workers' compensation claims are attributed to employees slipping on slick floors, and are the leading cause of occupational injury for people aged 15-24 years. Falls account for over 8 million hospital emergency room visits, representing the leading cause of visits (21.3%). Slips and falls account for over 1 million ER visits, or 12% of total falls.

Many warehouse spaces develop condensation problems when cold materials, such as metal, are brought into a warmer space. It may take hours or even days for the temperature of the delivered product to approach the inside air temperature.

During this warm-up period, the item’s surface temperature is initially below the dew point temperature of the air, leading to condensation on the surface. This moisture can lead to corroded metal, damp packaging and paper, and a host of other issues. 

What are some sweating slab solutions?

Some successful tactics to minimize condensation are:

  • A dehumidification system (air conditioning) to decrease the moisture content of the air. 
  • A heating system to increase the air temperature or surface temperature.
  • Air movement across cold surfaces to increase the surface temperature and decrease the amount of time that warm air is in contact with cold surfaces. 

Because large industrial spaces are often impractical, or at very least expensive to heat and cool, air movement is both the simplest and most affordable solution.

Heat transfer from the air to the surface can occur up to 2.5 times faster by increasing the air speed by 100 feet per minute (1.2 miles per hour). A faster warm-up time coincides with less condensation and less chance for corrosion.

Large diameter, low speed fans thoroughly and gently mix the air, sending warm air down from the rafters. This results in only slight temperature differences from floor to ceiling and wall to wall and the elevated air speed needed to reduce condensation at the floor. 

Case in point

Pallet manufacturer John Rock Inc. of Coatesville, Pa., struggled with moisture management on two levels; a quarter-million feet of green hardwood moving through their facility each shift, and a sweating concrete slab. They also inadvertently compounded their safety issues by designing their new production facility with a slick floor.

“We spent a lot of money to make sure we had a very smooth floor so we could move efficiently,” said Business Development and Purchasing Manager Penn Cooper. “We created a huge skating rink issue, just because it’s wet.”

John Rock Inc. uses lage diameter, low speed fans to thoroughly mix the air, resulting in only slight temperature differences from floor to ceiling and reducing the opportunity for condensation to form. The previously perilous floor remains dry, allowing employees and forklifts to travel safely, while gentle air movement through the stacks of newly minted pallets keep mold to a minimum.

“The fans dramatically improve the safety here,” Cooper said. “They’ve been a real blessing for us. I never would have thought it would work so well.” 

Erin Hsu is a senior copywriter for Big Ass Fans.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me