Autonomous snowplow, controls, feedback

Dunwoody College of Technology students made an autonomous snowplow for an Institute of Navigation engineering competition, installing a control system for steering/propulsion and creating a feedback system using sensors and optical encoders. System integration challenges included PLC parameters and motor integration. See photos, diagram.

10/03/2011


Above the plow, a Banner U-Gage ultrasonic sensor with a sensing range of 150 mm to 1 meter detected distance on the U-shaped course. Courtesy: E.J. Daigle, Dunwoody CollegeWith a team objective to “apply hands-on skills and teamwork to find real-world solutions,” Dunwoody College of Technology students and team mentors made an autonomous snowplow for an Institute of Navigation  engineering competition, installing a control system for steering/propulsion and creating a feedback system using sensors and optical encoders. The entry won third place in a collegiate Autonomous Snowplow Competition.

Dunwoody’s team had five AAS degree–seeking students and three faculty advisors: James Jorgenson is a student in engineering drafting and design. Michael Carnis, Keith McClelland, Josh Moses, and Nigel Ystenes are automated systems and robotics students. John McShannock, automated systems and robotics instructor, E.J. Daigle, robotics and manufacturing director, and Tim Flugum, physics instructor, served as mentors.

E.J. Daigle, robotics and manufacturing director, Dunwoody College, was among three faculty mentors who mentored students in the 2011 Annual Autonomous Snowplow Competition. Courtesy: E.J. Daigle, Dunwoody CollegeDunwoody received two riding lawn tractors as a donation from faculty. The goal was to convert one tractor into a snowplow by purchasing a plow blade, installing a control system for steering/propulsion, and creating a feedback system using sensors and optical encoders. The team sought a simple solution using its strengths with machining skills, PLCs, and electronics. The automated plow had to be powerful enough to remove snow using a 1-meter-wide path in one pass, robust enough to survive the Minnesota winter, and intelligent enough to navigate the U-shaped course.

Troubleshooting

According to the project report, challenges included integration of hardware, navigation sensors, and plow operation.

Under construction: Mechanical dimensions of the Dunwoody College 2011 automated plow were 78-in. L x 48-in. H x 44-in. W. Courtesy: E.J. Daigle, Dunwoody College“The mower we wanted to use had major wire harness problems. Many of the wires were missing, and as we were cutting the steering shaft with a torch we did more damage.” The older tractor also used a threaded lead screw with a collar that rode on the screw, the “preferred method for steering; however, after much work on other systems this tractor was deemed inadequate, and we selected the second tractor. Since we had two tractors, we were able to use the first one as a sacrificial lamb for the purpose of learning.”

Motor integration

Tractor drive system was spring loaded to drive. Students redesigned the mechanism to be spring loaded to the safe position; one pneumatic cylinder engages the clutch, tightens the drive belt, and releases the brakes. Courtesy: E.J. Daigle, Dunwoody Colle“We also had some issues with our first attempt at steering control. At first, we selected a stepper motor to turn the steering shaft. The driver chip we used to control it was unable to handle the current that the motor required. This led us to try switching relays with the driver and then running the stepper with the relays. We prototyped this using mechanical relays but they would not switch fast enough, so we decided to purchase some solid-state relays. The solid-state relays we bought were surplus items, and one was bad when we got it. We replaced the bad relay and then fried another one.

The encoder provided resolution of 15 degrees per hole for a total of 24 holes equally spaced around the circumference of the encoder wheel. Courtesy: E.J. Daigle, Dunwoody College“We gave up on the relays and decided to build our own switching circuit. We used high-power transistors and managed to achieve a top speed of about 24 rpm. We were unable to supply a full 5 V to the stepper so our torque was lower than it should have been. We managed to get 4 V to the stepper...enough to turn our steering shaft with a 5-to-1 gearbox, but it would only turn it in one direction reliably. We then decided to eliminate the stepper and found a 12V dc, 31 rpm motor [from Grainger] that also had sufficient torque to reliably turn the steering shaft.”

Encoder wheel

Controls: 2 V dc is electrically grounded to the tractor chassis. The 12/24 Siemens OBA4 Logo PLC was used, operating on 12 or 24 V dc, with 12 or 24 V dc inputs. Relay contacts deliver up to 10 amps. Courtesy: E.J. Daigle, Dunwoody College“We then attached an encoder wheel to the coupler. The encoder gives us a resolution of 15 degrees per hole for a total of 24 holes equally spaced around the circumference of the encoder wheel. We have also mounted a slotted opto-coupler so that the encoder wheel passes through the slot and pulses the signal from the opto-coupler. We use the signal from the opto-coupler to increment or decrement an up-down counter. When we turn the wheels right, the counter will increment until it reaches a set value. When we are ready to turn the wheels back to straight, the counter will decrement until it reaches 0. We change the direction of rotation by using two separate relays to reverse the polarity of the voltage applied to the power leads on the motor.”

PLC specifications

A navigational flow chart helped with control logic for the Dunwoody College 2011 autonomous snowplow. Courtesy: E.J. Daigle, Dunwoody CollegeFor the programmable logic controller (PLC), “we used a Siemens logo type OBA4 with 2 analog inputs and 6 discrete inputs. We did not consider...that we would not have access to built-in math functions when we selected this PLC. This made it almost impossible to do a comparison between two sources of input, and that meant we could not easily do course corrections.” Inputs I7 and I8 on the PLC also allow the use of analog input (0-10 V dc) for the analog distance sensor. A 4-input expansion module helped drive the tractor from a local joystick for on-site loading, unloading, and setup.

Total hardware project cost was estimated at $3,309; actual cost was $949 thanks to donations from faculty, Banner Engineering, and Cambridge Metals and Plastics. The Dunwoody College of Technology entry placed third competing against five university entries in the 2011 Annual Autonomous Snowplow Competition.

If you like Minnesota in January (or if you like autonomous snow plows even more than you like Minnesota in January), the Second Annual ION Autonomous Snowplow Competition is Jan. 26-29, in St. Paul.

www.autosnowplow.com 

www.dunwoody.edu/manufacturing 

Photo gallery, more project details See results and video. 

Pack Expo 2009: Students compete to find best palletizing solution

- Edited by Mark T. Hoske, CFE Media, Control Engineering; posted by Chris Vavra, Control Engineering, www.controleng.com 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me