Automated gripper set for handling and assembly systems

Parallel, three-point, radial and angle DHxS grippers from Festo are designed for handling and assembly systems and have gripping force retention and overload protection for safety.

03/23/2012


The parallel, three-point, radial and angle gripper series DHxS from Festo offers increased reliability in a range of sizes and stroke lengths. Courtesy: FestoThe parallel, three-point, radial and angle standard grippers, DHxS, from Festo are compact and offer reliability in the gripping process. Standard grippers are the first choice for cost-effective, lightweight and compact construction of handling and assembly systems. The parallel, three-point, radial and angle gripper series DHxS from Festo features optimized gripping force retention and overload protection as well as integrated sensor slots. It offers increased reliability in a range of sizes and stroke lengths.

A number of features ensure reliability and precision. The integrated fixed restrictor provides an effective safety buffer, protecting against overloading during high-speed gripper motions and preventing damage due to excessive forces. The integrated sensor slots in the medium and large sizes offer the advantage of cost-effective stroke sensing via sensors SMx. Their successful integration has resulted in a slim, compact design without any interference contours caused by external sensors. The new, compression spring-assisted gripping force retention provides more security in the event of a pressure failure. In addition, T-slot guides increase the torque resistance of the gripper jaws.

The double-acting piston drive gives the standard grippers stable kinematics and maximum repetition accuracy. A wide range of mounting options in the form of threaded, fitting and centering holes make the new generation of Festo standard grippers very flexible to mount. 

The parallel and three-point grippers DHxS have a lightweight aluminum housing with integrated receiving hole for the pneumatic piston. The force generated by the linear motion is transferred to the low-backlash gripper jaws by means of lever kinematics. Since the lever is indirectly in mesh with the two gripper jaws via a piston rod, there is no need for additional synchronization.

The pneumatic pistons of the double-acting DHxS radial and angle grippers act on the gripper jaws, mounted on pivots in a gripper jaw guide, by means of a slotted guide system. As with parallel and three-point grippers, this means that there is no need for separate synchronization.

Festo

www.festo.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com 

See more on motors, drives, and motion control from Control Engineering at http://www.controleng.com/new-products/motors-and-drives.html 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me