Aspirating smoke detectors

FAAST XS aspirating smoke detectors enable users to better serve the needs of small data centers, environmentally challenging spaces like manufacturing or process plants.

04/14/2016


FAAST XS aspirating smoke detectors enable users to better serve the needs of small data centers, environmentally challenging spaces like manufacturing or process plants, or any area within a facility where standard spot smoke detectors are subject to nuisance alarm conditions. This smaller FAAST unit covers up to 5,000 sq ft and delivers all the features of FAAST, such as the ability to be configured for very early warning, early warning, and standard fire protection. Other features include programming flexibility, multi-alarm levels and two sensitivity modes, ultrasonic flow sensing for pipe and chamber airflow measurements, early notification of pipe network trouble conditions, and built-in email event notification to appropriate personnel.

Notifier

www.notifier.com


This product is a Finalist in the
Consulting-Specifying Engineer 2016 Product of the Year program. View more Finalists and cast your vote at www.csemag.com/votepoy (voting closes June 30, 2016).



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me