ASHRAE Student Design Competition Winners Announced

08/24/2006


Night pre-cooling, naturally daylit areas and low-emission HVAC systems are some of the sustainable measures selected by students as part of ASHRAE’s 2006 Student Design Competition.

This year’s competition focused on the mixed-use renovation of the Dallas Power & Light building in a historic area of Dallas. The renovation includes converting the majority of the former office building into residential apartments, with retail space occupying the first floor of the building. Awards were announced in three categories: HVAC system selection, HVAC system design and architectural design.

The winning entries in the HVAC system selection and HVAC system design categories were awarded to the same team from The Pennsylvania State University: Justin Bem, Kevin Kaufman, David Melfi, Jon Gridley, Jessica Lucas and Yulien Wong. Their faculty advisor is William P. Bahnfleth, Ph.D., P.E.

For the HVAC system selection category, the students selected water-source heat pumps, giving the system a life-cycle cost of $7,464,000. The system selected calls for water-source heat pumps to parallel the one rooftop unit serving floors two through 20 and an additional rooftop unit for the first-level retail area. This system allows for easily converting first-level retail space to a new function, limits maintenance disruption to individual apartments and the roof, and allows for separate metering of retail space.

The ventilation systems were evaluated using Standard 62.1 and on their ability to fit into available mechanical room and shaft space. The option chosen was a rooftop unit paralleled by WSHP for residential units and a rooftop unit serving the retail areas. The students said, “The separation of the two types of spaces allows for better flexibility in the system and allows for future growth.”

The system also allowed for lower cost and emissions as well while allowing the building meet Standard 90.1 without compromising historic integrity of building.

For the HVAC system design category, the students designed a decoupled outdoor air system with a parallel sensible system with an energy cost of $4.72 per sq. ft. per year.

Because the mechanical penthouse on the second-floor roof of the annex was so close to the ground, dealing with architectural, environmental and acoustical impacts were serious considerations. Two of the solutions the students used were nighttime pre-cooling with unconditioned night air and fan-only energy for the retail spaces to reduce cooling load during the day. The students also used a dedicated outdoor air system.

First place in the architectural design category was awarded to Alissa Ogen and Sonia Carias of Savannah College of Art and Design. Their faculty advisor is Emad M. Afifi, Ph.D. The students, who were required to design a mixed-use collegiate space, designed a student activities center complete with student dormitories, a theater, recycling centers, an amphitheater, retail, landscaping and dining space.

The entry’s sustainable design features included pervious sidewalk materials; photovoltaic glass panels inside the cafeteria; translucent, diffuse light-transmitting walls; and reflective roofing materials. The students’ design also included a naturally ventilated atrium near the lobby and a naturally daylit cafeteria that is also shaded to save on energy costs.

Awards will be presented at ASHRAE’s 2007 Winter Meeting Jan. 27-31 in Dallas. Winning student groups will each have a poster presentation to display their projects at the meeting.





Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me