ASHRAE provides guidance on energy audits

ASHRAE's second edition of Procedures for Commercial Building Energy Audits provides advice for engineers, energy auditors, building owners, managers, and government entities.

12/06/2011


ASHRAE has released updated guidance on building energy audits. While energy audits are a commonly used component of the industry, there is great diversity in the services delivered to customers, and little industry standardization. The second edition of Procedures for Commercial Building Energy Audits promotes best practices, provides “how-to’s” and fills a void in available information for engineers, building owners, managers and government entities. The new publication includes time-saving tips for energy auditors, how to hire an auditor, what to ask for in a comprehensive audit report and how to build a successful energy efficiency retrofit team.

“As we work to reduce energy consumption in our commercial buildings, we want to ensure that recommendations are cost effective, technically feasible, maintain safety and comfort and result in significant energy savings” Jim Kelsey, a member of Technical Committee 7.6, Building Energy Performance, and who oversaw the writing of the updated publication, said. “This volume focuses on how to improve energy audit best practices. Providing the best audits that we can will help move the industry forward to net zero buildings.”

Additionally, the publication addresses how to build a successful team, analytical methods, successful approaches to site visits, incorporating on-site measurements, economic evaluation of measures and how to organize an energy audit report that promotes action on the part of building owners and managers. It includes many tips for conducting energy audits and reviewing results prepared by others. For example, the top things to check for in when reviewing an audit report include verifying that:

  • Proposed measures are feasible and appropriate for the building;
  • Proposed measures meet applicable building codes;
  • Data are internally consistent;
  • Savings estimate methods follow established principles and methods;
  • Estimates of potential energy savings are reasonable compared to quick estimates and historical energy use;
  • Proposed cost estimates are reasonable relative to field experience;
  • Interactions between EEMs are identified and addressed;recommendations and report meet the project scope, goals and client’s needs;
  • Any financial discussion includes current and viable mechanisms available per the tax structure, location, and motivations of the client.

Another benefit of the new publication is a greatly expanded section of forms and template analyses, including “live” Excel spreadsheets, checklists and equipment-specific forms suitable for field collection of detailed commercial building data.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me