ASHRAE 32P open for public comment

ASHRAE Guideline 32P aims to improve the performance of all buildings by providing guidance on optimizing operation and maintenance of buildings to achieve low costs without sacrificing safety or functionality.

06/06/2011


The proposed ASHRAE Guideline 32P, Sustainable, High Performance Operation and Maintenance, currently open for public comment until July 4, 2011, will reportedly help improve the performance of all buildings by providing guidance on optimizing operation and maintenance of buildings to achieve the lowest economic and environmental life cycle cost without sacrificing safety or functionality.

The guideline will apply to the ongoing operational practices for buildings and systems with respect to energy efficiency, occupant comfort, indoor air quality, health, and safety. These systems include the building envelope, HVACR, plumbing, complementary energy systems, and utilities and electrical systems.

The guideline contains recommendations for three levels of building oversight: senior managers, facility managers, and technicians. Checklists for tracking the appropriate steps are reportedly being taken to move toward high-performance operation and maintenance are included for each.

Among the items on the checklist for facility managers are:

  • Develop and implement protocols for good facility/system documentation.
  • Investigate, identify, and implement appropriate levels of building intelligence.
  • Identify and implement appropriate performance metrics.
  • Benchmark against other similar facilities.
  • Establish performance baselines and targets. Institute a system for regular reporting and evaluation.

It is said that the guideline will provide the next steps beyond compliance with ANSI/ASHRAE/ACCA Standard 180, Standard Practice for Inspection and Maintenance of Commercial Building HVAC Systems, and provide concepts, methods and details that meet the intent of the “minimum standards of care” under ANSI/ASHRAE/USGBC/IES Standard 189.1, Standard for the Design of High Performance Green Buildings.

- Edited by Amanda McLeman, Consulting-Specifying Engineer, www.csemag.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me