ASHRAE 188P open for public comment

ASHRAE 188P is open for a public review. Standard 188P, Prevention of Legionellosis Associated with Building Water Systems, specifies what must be done to control the spread of legionellosis.

01/31/2013


Standard 188P, Prevention of Legionellosis Associated with Building Water Systems, specifies what must be done to control the spread of legionellosis. The standard helps facility managers/owners understand how to apply the available information on Legionella effectively in order to prevent cases of legionellosis associated with building water systems.

The proposed standard underwent an earlier public review in June 2011 and is currently open for a third public review until March 11, 2013. For more information, visit www.ashrae.org/publicreviews.

William McCoy said the committee received more than 150 comments during the 2011 review. The input helped the committee in clarifying many aspects of the standards. Changes being proposed to the third review based on that input, include:

  • Clarifications made to definitions in Section 3, Definition of Terms and a new term was defined.
  • Clarifications made to Section 5, Risk Characterization. Those changes were substantive because building characteristics were reorganized into two subsections for clarity, subsections 5.2 and 5.3.
  • Reorganization of Table 1, Determining Preventative Measures Required for Buildings. The improvements reference two subsections of Section 5 (Sec 5.2 and 5.3).
  • Creation of a new subsection, 7.4, Water System Treatment and Management Program, in Section 7. Commenters indicated there should be specifications for a “water system treatment and management program” for buildings with none of the risk characteristics (now listed in Sec 5.2) but with any of the equipment specified (now listed in Sec 5.3),.
  • Clarifications to Section 8 regarding wording, references, cited regulations and informative notes.

Compliance with the standard requires facility managers/owners to formally take responsibility for controlling Legionella in their building water systems, while at the same time acts as a defense against accusations of negligence in those cases which are caused by the hazard from unknown sources.

Standard 188P also covers the potable water system in buildings, which are not treated as often as cooling towers, and will hold facility managers/owners accountable for properly managing the entire building water system both potable and utility water.

The standard differs from ASHRAE Guideline 12, Minimizing the Risk of Legionellosis Associated with Building Water Systems, in that while the guideline gives recommendations about how to treat various building water systems, the standard specifies the practice of exactly what must be done with all those recommendations.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me