Arc flash system

GE's Multilin A60 Arc Flash System uses light and pressure wave detection technology to detect and initiate a trip signal in the event of an arc flash condition.

06/07/2013


The Multilin A60 Arc Flash System uses a trip signal to minimize damage to medium-voltage switchgear and motor control center applications. Courtesy: GEGE's Multilin A60 Arc Flash System uses light and pressure wave detection technology to quickly and reliably detect and initiate a trip signal in the event of an arc flash condition. By initiating the trip signal, the Multilin A60 helps minimize equipment damage and reduce the costs associated with unplanned downtime and lost production. Designed for medium-voltage switchgear and motor control center applications, the Multilin A60 is a protection relay independent, stand-alone device that can be used in new or existing installations for continuous monitoring and fast detection of an arc flash event. Its design includes five arc flash sensors for optimal coverage, and its scalability allows multiple Multilin A60 devices to be connected, delivering increased fault isolation for reduced equipment damage. The Multilin uses sensor auto-calibration, eliminating the need for CT connections or setup software, reducing total operation and maintenance costs. The Multilin A60 comes equipped with a self-test feature that monitors the health of the sensors, the full length of the fiber cables, and the unit itself, eliminating the need for periodic testing.

General Electric

www.ge.com 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me