APC Symmetra PX 250/500kW supports parallel configurations up to 2000kW

The Symmetra PX250/500kW offers a modular, hot-scalable system consisting of dedicated and redundant modules.

01/27/2011


APC by Schneider Electric, a producer of integrated critical power and cooling services, new parallel capabilities of the Symmetra PX 250/500kW three-phase modular and hot scalable uninterruptible power supply (UPS). Schneider Electric APC Symmetra PX This new firmware ships standard on all Symmetra PX250/500kW units which can now be paralleled to deliver up to 2 MW of power protection, or 1.5MW in a system level redundancy (N+1) configuration. The Symmetra PX250/500kW reportedly provides unprecedented scalability and availability up to 2000 kW, giving customers the unrivalled flexibility to scale their data centers as business needs require.

The Symmetra PX250/500kW offers a modular, hot-scalable system consisting of dedicated and redundant modules - power, intelligence, battery and communications - all engineered into a design that allegedly makes installation, future expansion and serviceability faster and easier. Each system is scalable in 25kW increments up to 500kW with the ability to run up to four systems in parallel to provide 2MW of redundant power protection. The architecture gives IT managers the ability to right-size power and runtime as demand grows or as higher levels of availability dictate.

In addition to all the current features and reported capabilities of the Symmetra PX250/500kW - independently verified efficiency of greater than 96% down to 35% loading, high density space saving design, modular, hot scalable with a system-wide mean time to repair of less than 10 minutes, and near silent operation - the release of this new firmware adds:

  • Parallel up to 4 units - for 2000kW or 1.5MW in an N+1 system configuration of power protection capacity.
  • Energy monitoring – Has the ability to calculate and display the energy (kWh) delivered on the output of each unit.
  • Multi-language support – can be localized in seven languages to provide better understanding of alarms/events and display information.
  • Shortened recharge time – 20% charge capacity at loads less than 100%, can be used to recharge units for faster recovery and to maximize system availability.

The Symmetra PX250/500kW can be managed through APC’s InfraStruxure Management Software Portfolio and can be integrated into data centers for a complete solution through built-in management software including InfraStruxure Designer, Central, Capacity Manager, and server access support.

www.apc.com

APC by Schneider Electric

www.schneider-electric.us Schneider Electric



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me