ANSI Rejects Ventilation Rate Appeal

The American National Standards Institute (ANSI) Appeals Board has rejected a final appeal of an addendum to ANSI/ASHRAE Standard 62-2001, Ventilation for Acceptable Indoor Air Quality. Addendum 62n was approved for publication at the society's 2003 Annual Meeting. Six appeals were filed and later denied by ASHRAE.

11/01/2004


The American National Standards Institute (ANSI) Appeals Board has rejected a final appeal of an addendum to ANSI/ASHRAE Standard 62-2001, Ventilation for Acceptable Indoor Air Quality . Addendum 62n was approved for publication at the society's 2003 Annual Meeting. Six appeals were filed and later denied by ASHRAE.

The ANSI Appeals Board's decision upholds a decision made earlier this year by its Board of Standards Review, which voted to deny all appeals made to ANSI, thereby upholding its earlier approval of the addendum.

The addendum specifies the determination of design ventilation rate used for application of the ventilation rate procedure. The procedure specifies ventilation rates that can be easily measured for compliance verification and allows designers to determine appropriate rates and reduce the potential for over-ventilation in some densely occupied spaces, according to committee chair David Butler, P.E. The standard is now written in mandatory, enforceable language and is focused on minimum requirements.

The addendum recognizes that air pollutants are generated by building contents and occupant activities, and as such, bases ventilation requirements on the number of people the space is expected to hold, as well as the space's floor area. Calculating minimum outdoor ventilation requirements for a building ventilation system is done using the "additivity" procedure.

In an office building, for example, the procedure determines the outdoor air requirement for each type of space (offices, conference rooms, etc.), and these requirements determine the amount of outdoor air intake required at the air handler.

A spreadsheet, 62n.VRP.xls, helps to simplify multiple space ventilation calculations. It's available under the SSPC62.1 directory at ftp.ashrae.org . And Addendum 62n is available via the "standards addenda index" shortcut at ashrae.org .





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me