An Exclamation on XML

A big buzz at the AHR Expo was talk of XML and what it may mean for the controls industry. As a pre-session to its day long symposium, Dallas-based Clasma assembled a number of integrators and movers and shakers in the real estate community to discuss trends driving what they feel is a "convergence" of technologies—most notably IT and mechanical/electrical systems—that will signific...

02/01/2004


A big buzz at the AHR Expo was talk of XML and what it may mean for the controls industry. As a pre-session to its day long symposium, Dallas-based Clasma assembled a number of integrators and movers and shakers in the real estate community to discuss trends driving what they feel is a "convergence" of technologies—most notably IT and mechanical/electrical systems—that will significantly alter the way buildings are operated in the near future.

"There's a lot of confusion out there right now due to the enormity of the changes happening," says Anto Budiardjo, president of Clasma, the symposium's sponsor and the organization that produces the Builconn show.

Just a short time later, OBIX, the Open Building Information Exchange, a fledgling coalition of building controls companies, presented their plan for launching a new standard for Internet-based XML communication for building control systems.

According to Trane's Paul Ehrlich, the group's chairman, the notion of implementing an industry standard using XML is not to replace BACnet or LonWorks, but rather to simply serve as a vehicle for both protocols to deliver data from those systems to wherever necessary.

Ehrlich said the group hopes to have a draft completed by the end of the year and a rough draft up by April. Visit www.OBIX.org for more, including an open forum.

At the symposium itself, co-sponsored by the Continental Automated Buildings Assn., speakers outlined a number of issues, including education, coordination and a need for standards.





Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me