An enlightened look at photovoltaic cost

Given the double digit growth in the photovoltaic industry, PV conversion of sunlight is quickly making economic sense. There are two basic types of PV systems: grid-connected and remote-storage. Grid-connected systems are connected directly to the building power system to supplement the power delivered by the local utility.

09/01/2007


Given the double digit growth in the photovoltaic industry, PV conversion of sunlight is quickly making economic sense.

There are two basic types of PV systems: grid-connected and remote-storage. Grid-connected systems are connected directly to the building power system to supplement the power delivered by the local utility. Remote systems often are deployed in areas where the cost to extend utilities is prohibitive.

Three types of commercially viable modules are monocrystalline silicon, polycrystalline silicon and amorphous silicon. The relatively new amorphous-silicon thin-film technologies often are deployed as integrated roof, building skin or canopy systems, called building integrated photovoltaic systems (BIPVs). BIPVs offer the advantage of multiple use, as both solar shade and electrical generation.

One should consider relative solar angles and siting issues to site an array properly. In our hemisphere, the sun tracks along a southerly route due to the earth’s inclination to the sun. This makes it important to orient the array to the south. Ideally, a zero azimuth is the optimal orientation, but a 10-degree variation one way or the other won’t affect a cost-effective output of the system. Select a tilted angle close to the array’s latitude.

One can expect the present cost to be in the range of $5 to $8 per peak watt (Wp), including installation costs and any burdens, though I have seen estimates as low as $4 to $5 per Wp. The final cost of a 20-kilowatt peak (kWp) fixed-grid system should be about $160,000.

A good benchmark is the USGBC LEED credit available with a 5% system—one that supplies no less that 5% of a facility’s demands. Smaller systems are equally viable.

It is important to select a design team with an intimate knowledge of simulation and modeling techniques. A baseline calculation using an energy modeling tool will be required.

A typical system produces about 9 Wp to 10 Wp per sq. ft. and about 10 kWh to 12 kWh per sq. ft. per year, depending on the geographic siting of the array. These numbers are improving by significant margins based on improved modules, but they should hold for budget purposes over the next year or so.

Let’s look at a 100,000-sq.-ft. office building. Given 6 Wp per sq. ft. (use demand, not connected load) this value becomes 600 kWp:

600 kWp X 5% = 30 kWp

30 kWp X $8 per Wp = $240,000

These numbers are conservative, but should get budgeting in the ballpark. For a reality check, consider that if the office building is constructed for $90 per sq. ft., it would cost $9 million. The $240,000 represents about a 2.6% increase in construction cost. In San Antonio, Texas, for example, one can expect a payback in 10 to 15 years. Payback could be half that time in areas with higher energy rates. Utilities are offering help in capitalizing PV projects because it improves their adherent to renewable portfolio standards. Considering that a systems offer a 25 year or more useful life, it will be generating free electricity for half or more of its useful life.

Editor’s note: A longer, more detailed version of this article can be found in the Electrical Community at www.csemag.com .



Considerations in PV design

Building integrated photovoltaic systems (BIPVs) function as both solar shade and electrical generation

Federal, state and local jurisdictions offer tax rebates for PV use

Utilities are stepping up to the plate by offering help in capitalizing PV

USGBC LEED credit offers a benchmark for the percentage of power PV provides



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me