Albany County Sewer District: Incineration Waste Heat Recovery/Co-Generation Project

Addition to existing building: Albany County Sewer District: Incineration Waste Heat Recovery/Co-Generation Project; CDM Smith

08/09/2012


A cogeneration unit is set in place during construction. Courtesy: CDM Smith (Click to enlarge)Project name: Albany County Sewer District: Incineration Waste Heat Recovery/Co-Generation Project

Location: Menands, N.Y.

Firm name: CDM Smith

Project type, building type: Addition to existing building, manufacturing

Project duration: 4 years

Project completion date: Dec. 1, 2012

Project budget for mechanical, electrical, plumbing, fire protection engineering only: $870,000

Engineering challenges

Issues related to this project included ensuring that the equipment would meet all applicable U.S. standards for the interconnection with the utility, ensuring that the plant personnel were comfortable operating the equipment, and helping the owner secure funding to move the project forward.

Solutions

The CDM-led team was hired to independently evaluate and determine the feasibility of utilizing the high-temperature (1,000 to 1,250 F) exhaust gas flow from the incinerators to an organic rankine cycle system and drive a turbine generator. The CDM team also provided support to the Albany County Sewer District for an application to the New York State Energy Research and Development Authority (NYSERDA), which led to a grant for up to $2 million in engineering and construction funding. Additionally, the CDM team provided support to the district for an application to the New York State Environmental Facilities Corporation (NYSEFC), which led to a $5.8 million in Green Innovation Grant Program (GIGP) funding. Results of the study predict the waste heat from the incinerators is expected to co-generate 3.3 million kWh per year (enough to power 3,000 households); reduce the district’s natural gas consumption by 100,000 therms per year, for a value of $475,000 annually at present rates; and reduce greenhouse gases by 1,445 tons/year. In addition, thermal energy reclaimed will be utilized for space heating, creating a combined heat and power (CHP) system.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me