Air, gas flow meter receives FM and FMc approval

The future-ready ST100 Series Thermal Mass Air/Gas Flow Meter from Fluid Components International (FCI) has received FM and FMc approval, assuring FCI’s customers that it conforms to the highest national and international safety standards.

05/03/2012


The future-ready ST100 Series Thermal Mass Air/Gas Flow Meter from Fluid Components International (FCI) has received FM and FMc approval, assuring FCI’s customers that it conforms to the highest national and international safety standards.

FCI flowmeter gets FM and FMc approvals.The FM Approved mark, and Canadian FMc Approved mark, assure FCI’s customers that the ST100 Flow Meter has been deemed to perform reliably and safely, backed by independent scientific research and testing. FM Global certifies products to assure customers that they conform to the highest national and international safety standards for loss protection and risk management. The ST100 Flow Meter has received FM and FMc approvals: Class I, Division 1, hazardous locations, Groups B, C, D; Class II and III, Div 1 Groups E, F, G; Nonincendive Class I  Division 2  Groups A, B, C, D; Nonincendive Class II, Division 2 Groups E, F, G.


The revolutionary ST100 Series Flow Meter sets a new industry benchmark in process and plant air/gas flow measurement instrumentation, offering the most feature-rich and function-rich electronics available today.  The leading-edge ST100’s superior flow sensing performance delivers unsurpassed adaptability and value to meet plant gas flow measurement applications for today and tomorrow.

The ST100 Series Air/Gas Flow Meter was developed in response to discussions with a wide range of instrument, process and plant engineers, who wanted more comprehensive measurement information as well as the flexibility to adapt to future plant and process control technology they might deploy. Beyond continuously measuring, displaying and transmitting the industry’s most extensive array of parameters, the ST100 is the first thermal mass flow meter with a migration path to tomorrow. 

Whether the need is for 4-20 mA analog, frequency/pulse, alarm relays or digital bus communications such as HART, Fieldbus, Profibus or Modbus, the ST100 is thesolution. Should a plant’s needs change over time or an upgrade be desirable, the ST100 Flow Meter adapts as necessary with a plug-in card replacement that can be changed out by plant technicians in the field. That takes “never obsolete” to a whole new level in flow measurement instrumentation.

The ST100 Flow Meter’s unique graphical, multivariable, backlit LCD display/readout brings new meaning to the term “process information”. It provides the industry’s most comprehensive information with continuous display of all process measurements and alarm status, and the ability to interrogate for service diagnostics.

The user-friendly ST100 stores up to five unique calibration groups to accommodate broad flowranges, differing mixtures of the same gas and multiple gases, and obtains up to 1000:1 turndown.  An optional, patent-pending SpectraCal™ Gas Equivalency calibration method lets users select and switch between 10 common gases.   Also standard is an on-board data logger with an easily accessible, removable 2-GB micro-SD memory card capable of storing 21 million readings.

The ST100 is the first thermal flow meter to offer three different types of flow sensors to best match user applications.  The fast-response FPC-style is a fast response features an integral flow conditioner and protective shroud optimized for compressed air and clean gas applications.   The fast-response, general purpose FP-style features a protective shroud and is the sensor used with FCI’s VeriCal™ in-situ calibration option.  For wet or dirty gases, or erratic flows, the unshrouded S-style facilitates easy cleaning and provides a smoothed response.

The comprehensive ST100 Series is comprised of two core model families: ST and STP.   ST meters measure both mass flow and temperature, and the exclusive STP family adds a third parameter, pressure, making the ST100 the world’s first triple-variable thermal flow meter.  Both families include single-point and dual-element models as configurations outfitted with FCI’s exclusive in-situ calibration option, VeriCal. 

The ST100 can be calibrated to measure virtually any process gas, including wet gas, mixed gases and dirty gases.  The basic insertion style air/gas meter features a thermal flow sensing element that measures flow from 0.25 to 1000 SFPS (0.07 NMPS to 305 NMPS) with accuracy of  ±0.75 percent of reading, ±0.5 percent of full scale.  

Designed for rugged industrial processes and plants, ST100 Flow Meters include service up to 850 F (454 C) and are available with both integral and remote (up to 1000 feet [300 meters]) electronics versions. The ST100 is agency approved for hazardous environments, including the entire instrument, the transmitter and the rugged, NEMA 4X/IP67 rated enclosure.  Instrument approvals (submitted and pending) in addition to FM and FMc include ATEX and IECEx:  Zone 1, II 2 GD Ex d IIC T4.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me