AHA Consulting Engineers Inc.: Vertex Pharmaceuticals, Fan Pier Buildings A & B

New construction of an office building; parking garage/service station; research facility/laboratory

08/17/2015


Figure 1: Vertex Pharmaceuticals at Fan Pier in Boston. AHA provided MEP design for both the core and shell and fit-outs for both buildings, and all of the design work was completed in Autodesk Revit. Each building includes 16 stories of lab and office space with parking under both. Specialized design for this high-level project includes vivariums, BSL-2 labs, chemistry labs, MRI spaces, radiology labs, wet labs, and much more. Courtesy: Rendering by TSOI/ Kobus & AssociatesEngineering firm: AHA Consulting Engineers Inc.
2015 MEP Giants rank: 64
Project: Vertex Pharmaceuticals, Fan Pier Buildings A & B
Address: Boston, United States
Building type: Office building; Parking garage/service station; Research facility/laboratory
Project type: New construction
Engineering services: Automation, controls; Electrical, power; Fire, life safety; HVAC, mechanical; Lighting; Energy, sustainability; Plumbing, piping
Project timeline: 8/23/2011 to 6/30/2014
MEP/FP budget: $2,422,500

Challenges

The project was to design two high-rise towers to accommodate laboratories and office space. The buildings have substantial chemistry use on the lower floors and a full-floor vivarium. Due to the substantial lab usage, design features were needed to minimize energy consumption. Another challenge with the project was that due to Federal Aviation Administration (FAA) restrictions and the buildings being within the Logan Airport flight path, the total height of the buildings had to be limited. This restriction affected equipment selections and limited floor-to-floor heights for the office areas on the upper floors.

Solutions

Our MEP design solutions included:

  • Enhanced distribution of systems through coordinated shafts to allow for system flexibility to accommodate concentrated or light chemistry use on the lower floors
  • Designed backup systems that were cross-connected to the core building systems with matching controls to allow the vivarium area to be maximized and mechanical systems to be minimized
  • Minimized large ductwork distribution, applied effective pipe routing, and incorporated fan-coil units to result in minimum ceiling plenum area
  • Applied variable air volume controls for fume-hood exhaust systems, used sash controls and motion sensors, and applied a tight diversity of use to reduce equipment size, use, and energy
  • Coordinated various architectural features and engineered mechanical penthouse volumes to limit the height of equipment, including lightning-protection rods to result in a facility standing below maximum allowable FAA heights.


Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me