AHA Consulting Engineers Inc.: Primerica

New construction of a data center, office building.

08/14/2014


Data center. Courtesy: AHA Consulting Engineers Inc.Engineering firm: AHA Consulting Engineers Inc.
2014 MEP Giants rank: 51
Project: Primerica
Address: Duluth, Ga., U.S.
Building type: Data center, Office building
Project type: New construction
Engineering services: Automation/controls, commissioning/retro-commissioning, electrical/power, fire/life safety, HVAC/mechanical, lighting, energy/sustainability, plumbing/piping, and other
Project timeline: 9/16/2011 to 7/17/2013
MEP/FP budget: $365,000

Challenges

The project presented many challenges. The process of juggling concurrent core and shell design with interior design while maintaining budget and schedule was particularly challenging. But multiple coordination meetings (both face-to-face and by web meetings) allowed the engineering team to blend well with the other team members and clients. Design challenges included the blending of a television recording studio, a mission critical data center, and a 200-seat full-service cafeteria into a corporate office environment. The project is the corporate headquarters for the client, and all systems needed to be both dedicated to the use and yet blend together as one cohesive operation.

Aerial photo of the building (350,000-sq-ft building). Courtesy: AHA Consulting Engineers Inc.Solutions

The firm’s deep experience in design of all the project occupancies and applications, coupled with a dedicated team working in step with the architects, designers, and other team consultants, allowed the multiple facets of the project to blend into a common goal for all. Multiple (sometimes daily) face-to-face and web meetings allowed the team to be in sync with all players. It was critical that all stakeholders, including owners, clients and contractors, were involved to speak to scope, schedule, and budget. The design of the TV studio required understanding of acoustics and vibration as well as the need for separating the systems from the office core. Working with specific consultants and a collaborative give-and-take approach by all team members resulted in a state-of-the-art studio. The firm’s experience in data center design for multiple clients allowed it to provide a reliable mission critical data center. The systems had to be designed without interlocking with the base building systems while residing within the same structure.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me